China energy efficiency labeling
Your current position: Home >> China Certification >> China energy efficiency labeling
Style and specifications of China energy efficiency labeling
Source: ShenZhenTobyTechnologyCo.,LtdPopularity: 1764Time: 2016-04-15【SMB】
In recent years, relevant departments of the state has issued a number of laws and regulations and related documents, situation and development direction of energy-saving work to develop a specific planning. Proposed to vigorously promote energy-saving product certification and energy efficiency labeling management system, and guide consumers to buy energy-efficient products.
At present, mandatory government procurement of products there are nine kinds: air conditioning, lighting products (including double end fluorescent lamp, self ballasted fluorescent lamps, single end fluorescent lamp, shaped fluorescent lamp ballasts), television, electric water heater, computer, printer, display, faucets. According to the government procurement procedures, for the nine categories of mandatory government procurement of products, energy-saving certification is still voluntary certification, but if the participation in the government procurement bidding, must through energy-saving certification.
Here, TOBY will introduce some of the content of the certification of energy-saving lamps:
(一) the style and specifications of the energy efficiency labeling
1 identified as the blue and white background color logo, the minimum length is 45 mm, the width of the minimum is 30 mm.
2 logo Name: China energy efficiency labeling (English name ENERGY LABEL CHINA), including the following:
Producer name or abbreviation
Product specification model
Energy efficiency rating
Nominal power (W)
tone
Initial light effect (lm/W)
Based on the energy efficiency of the national standard number
3 logo of the minimum style and specifications see the following chart:
(二) the energy efficiency testing project, definition and standards
Power: definition: in the rated voltage and rated frequency, the actual consumption of the power and the rated power is poor.
Standard: the difference shall not be greater than 15%.
The initial light effect: definition: ratio of self ballasted fluorescent lamp luminous flux and the measured power units for lumens per watt (lm/w}.
Standard: the limit value of the energy efficiency of the ballast fluorescent lamp is 3 of the energy efficiency grade in the following table.
Chromaticity tolerance: definition: the range of chromaticity coordinates of target lamp distance value.
Standard: less than 5 SDCM
Guangtong maintenance rate: definition: under the conditions prescribed burning, during the life of the engine to a specific time in the luminous flux and initial flux volume ratio percentage than that.
Standard: self ballasted fluorescent lamps light in 2000h, its luminous maintenance rate should not be less than 80%.
(三) test methods and main equipment of energy efficiency testing project
Test methods: lamp lamp number, 1H, installed in the above pre in the integrating sphere, light until n
Power is down to the rated power and near the stabilized, using computer software testing, test results are saved and record the minimum power and maximum luminous flux.